Junos OS: PTX Series: In an FTI scenario MPLS packets hitting reject next-hop will cause a host path wedge condition
13Vexday Risk Score
No sign of exploitation. No public exploitation artifact known so far.
ssvc Trackcvss 6.5epss 0.3%
exploitation probability
0.3%top 75% of all CVEs
observed exploitation
nono source reports it
An Improper Neutralization of Equivalent Special Elements vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS on PTX Series allows a unauthenticated, adjacent attacker to cause a Denial of Service (DoS).
When MPLS packets are meant to be sent to a flexible tunnel interface (FTI) and if the FTI tunnel is down, these will hit the reject NH, due to which the packets get sent to the CPU and cause a host path wedge condition. This will cause the FPC to hang and requires a manual restart to recover.
Please note that this issue specifically affects PTX1000, PTX3000, PTX5000 with FPC3, PTX10002-60C, and PTX10008/16 with LC110x. Other PTX Series devices and Line Cards (LC) are not affected.
The following log message can be seen when the issue occurs:
Cmerror Op Set: Host Loopback: HOST LOOPBACK WEDGE DETECTED IN PATH ID <id> (URI: /fpc/<fpc>/pfe/<pfe>/cm/<cm>/Host_Loopback/<cm>/HOST_LOOPBACK_MAKE_CMERROR_ID[<id>])
This issue affects Juniper Networks Junos OS:
* All versions earlier than 20.4R3-S8;
* 21.1 versions earlier than 21.1R3-S4;
* 21.2 versions earlier than 21.2R3-S6;
* 21.3 versions earlier than 21.3R3-S3;
* 21.4 versions earlier than 21.4R3-S5;
* 22.1 versions earlier than 22.1R2-S2, 22.1R3;
* 22.2 versions earlier than 22.2R2-S1, 22.2R3.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Affected products
Juniper Networks · Junos OS