CVE-2025-56498
CVE-2025-56498
Vexday Risk Score
13Low
SSVC decision (CISA)
Track
No exploitation signal → monitor
CVSS 5.3EPSS 1.7%KEV nãoPoC —Nuclei —Metasploit —Patch —
Lifecycle
03 Sep 2025Published on NVD
Recommendation: Monitor — no exploitation signal at the moment.
An OS command injection vulnerability exists in PLDT WiFi Router's Prolink PGN6401V Firmware 8.1.2 web management interface. The ping6.asp page submits user input to the /boaform/formPing6 endpoint via the pingAddr parameter, which is not properly sanitized. An authenticated attacker can exploit this flaw by injecting arbitrary system commands, which are executed by the underlying operating system with root privileges. The router uses the Boa web server (version 0.93.15) to handle the request. Successful exploitation can lead to full system compromise and unauthorized control of the network device.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
Affected products
n/a · n/a