← volver
CVE-2023-2637

Rockwell Automation FactoryTalk System Services Vulnerable To Use Of Hard-Coded Cryptographic Key

CVSS 7.3 HIGHEPSS 0.2%CWE-321
Vexday Risk Score
21Bajo
Decisión SSVC (CISA)
Track
Sin señal de explotación → monitorear
CVSS 7.3EPSS 0.2%KEV nãoPoC Nuclei Metasploit Patch
Ciclo de vida
13 jun 2023Publicada en NVD
Recomendación: Monitorear — sin señal de explotación por ahora.
Rockwell Automation's FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies.  Hard-coded cryptographic key may lead to privilege escalation.  This vulnerability may allow a local, authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. This may allow the threat actor to make malicious changes to the database that will be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required for this vulnerability to be successfully exploited.
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:H

¿Quieres saber si tu infraestructura está expuesta a esto?

Hablar con TrueHacking →