← volver
CVE-2023-28766

CVE-2023-28766

CVSS 7.5 HIGHEPSS 0.9%CWE-476
Vexday Risk Score
21Bajo
Decisión SSVC (CISA)
Track
Sin señal de explotación → monitorear
CVSS 7.5EPSS 0.9%KEV nãoPoC Nuclei Metasploit Patch
Ciclo de vida
11 abr 2023Publicada en NVD
Recomendación: Monitorear — sin señal de explotación por ahora.
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service. An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
Productos afectados
Siemens · SIPROTEC 5 6MD85 (CP300)Siemens · SIPROTEC 5 6MD86 (CP300)Siemens · SIPROTEC 5 6MD89 (CP300)Siemens · SIPROTEC 5 6MU85 (CP300)Siemens · SIPROTEC 5 7KE85 (CP300)Siemens · SIPROTEC 5 7SA82 (CP100)Siemens · SIPROTEC 5 7SA82 (CP150)Siemens · SIPROTEC 5 7SA86 (CP300)Siemens · SIPROTEC 5 7SA87 (CP300)Siemens · SIPROTEC 5 7SD82 (CP100)Siemens · SIPROTEC 5 7SD82 (CP150)Siemens · SIPROTEC 5 7SD86 (CP300)Siemens · SIPROTEC 5 7SD87 (CP300)Siemens · SIPROTEC 5 7SJ81 (CP100)Siemens · SIPROTEC 5 7SJ81 (CP150)Siemens · SIPROTEC 5 7SJ82 (CP100)Siemens · SIPROTEC 5 7SJ82 (CP150)Siemens · SIPROTEC 5 7SJ85 (CP300)Siemens · SIPROTEC 5 7SJ86 (CP300)Siemens · SIPROTEC 5 7SK82 (CP100)Siemens · SIPROTEC 5 7SK82 (CP150)Siemens · SIPROTEC 5 7SK85 (CP300)Siemens · SIPROTEC 5 7SL82 (CP100)Siemens · SIPROTEC 5 7SL82 (CP150)Siemens · SIPROTEC 5 7SL86 (CP300)Siemens · SIPROTEC 5 7SL87 (CP300)Siemens · SIPROTEC 5 7SS85 (CP300)Siemens · SIPROTEC 5 7ST85 (CP300)Siemens · SIPROTEC 5 7ST86 (CP300)Siemens · SIPROTEC 5 7SX82 (CP150)Siemens · SIPROTEC 5 7SX85 (CP300)Siemens · SIPROTEC 5 7UM85 (CP300)Siemens · SIPROTEC 5 7UT82 (CP100)Siemens · SIPROTEC 5 7UT82 (CP150)Siemens · SIPROTEC 5 7UT85 (CP300)Siemens · SIPROTEC 5 7UT86 (CP300)Siemens · SIPROTEC 5 7UT87 (CP300)Siemens · SIPROTEC 5 7VE85 (CP300)Siemens · SIPROTEC 5 7VK87 (CP300)Siemens · SIPROTEC 5 7VU85 (CP300)Siemens · SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1)Siemens · SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1)Siemens · SIPROTEC 5 Communication Module ETH-BD-2FOSiemens · SIPROTEC 5 Compact 7SX800 (CP050)

¿Quieres saber si tu infraestructura está expuesta a esto?

Hablar con TrueHacking →