CVE-2025-52873
Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource
Vexday Risk Score
21Bajo
Decisión SSVC (CISA)
Track
Sin señal de explotación → monitorear
CVSS 7.2EPSS 0.3%KEV nãoPoC —Patch —
Ciclo de vida
18 sep 2025Publicada en NVD
Recomendación: Monitorear — sin señal de explotación por ahora.
Cognex In-Sight Explorer and In-Sight Camera Firmware expose
a telnet-based service on port 23 to allow management operations such as
firmware upgrades and device reboots, which require authentication. A
user with protected privileges can successfully invoke the
SetSystemConfig functionality to modify relevant device properties (such
as network settings), contradicting the security model proposed in the
user manual.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N
Productos afectados
Cognex · In-Sight 2000 seriesCognex · In-Sight 7000 seriesCognex · In-Sight 8000 seriesCognex · In-Sight 9000 seriesCognex · In-Sight Explorer¿Quieres saber si tu infraestructura está expuesta a esto?
Hablar con TrueHacking →