← volver
CVE-2025-54810

Cognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replay

CVSS 8.6 HIGHEPSS 0.2%CWE-294
Vexday Risk Score
21Bajo
Decisión SSVC (CISA)
Track
Sin señal de explotación → monitorear
CVSS 8.6EPSS 0.2%KEV nãoPoC Nuclei Metasploit Patch
Ciclo de vida
18 sep 2025Publicada en NVD
Recomendación: Monitorear — sin señal de explotación por ahora.
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

¿Quieres saber si tu infraestructura está expuesta a esto?

Hablar con TrueHacking →