Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information
21Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 7.5epss 1.7%
probabilidade de exploração
1.7%top 25% das CVEs
exploração observada
nãonenhuma fonte reporta
ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.
CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
Produtos afetados
Rockwell Automation · ISaGRAF RuntimeReferências
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-159-04https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1131699https://www.cisa.gov/uscert/ics/advisories/icsa-20-280-01https://www.xylem.com/siteassets/about-xylem/cybersecurity/advisories/xylem-multismart-rockwell-isagraf.pdf