CVE-2024-23485
13Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 4.6epss 0.2%
probabilidade de exploração
0.2%top 92% das CVEs
exploração observada
nãonenhuma fonte reporta
Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access.
This issue affects: Gallagher Controller 6000 and 7000 9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), 8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Produtos afetados
Gallagher · Controller 6000 and Controller 7000