CVE-2025-31351
CVE-2025-31351
Vexday Risk Score
21Baixo
Decisão SSVC (CISA)
Track
Sem sinal de exploração → monitorar
CVSS 8.7EPSS 0.6%KEV nãoPoC —Nuclei —Metasploit —Patch —
Ciclo de vida
16 abr 2025Publicada no NVD
Recomendação: Monitorar — sem sinal de exploração no momento.
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25917)
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Produtos afetados
Siemens · TeleControl Server BasicQuer saber se a sua infraestrutura está exposta a isto?
Falar com a TrueHacking →