Lack of cryptographic protection in Wertheim SafeController 5400 enables RS-485 message sniffing and replay
41Vexday Risk Score
Sem sinal de exploração. Ela tem prova de conceito pública.
ssvc Attendcvss 8.6epss 0.2%
probabilidade de exploração
0.2%top 90% das CVEs
exploração observada
nãonenhuma fonte reporta
1 exploit(s) público(s)
The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N
Produtos afetados
Wertheim GmbH · Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller)PoCs públicas encontradas — 1
cve_referencesec-consult.com/vulnerability-lab/advisory/multiple-vulnerabilities-in-wertheim-safecontroller-hardware-for-vault-rooms-safe-deposit-locker-system-microcontroller/não verificado⚠ Recursos públicos, para você avaliar a exposição de sistemas que controla ou está autorizado a testar. Teste apenas com autorização.